Front Panel Features
- Line activity LEDs
- Printer output: sequential call#, date, time, digits dialed,
tone/pulse dialing, call connect, disconnect and duration of call, number of rings, audio
time and control condition, power on and down time, target case number and type of call.
- 16 Button control keypad- Used to control unit operation &
enter parameter setup program
- Liquid crystal display- Indicates current status of lines or
detailed information of a line. Also functions as a setup menu when altering the unit
parameters.
Number of Lines
- One standard-expandable to six
- Memory Capacity
- 1000 calls waited to be printed (optional)
- Digit Capacity- sixty (60)
Data Output-RS232 with multiple baud rates (optional)
- Telephone Line Loading
Bridging & Isolated from Ground-DC- 10 M ohm AC-200 K ohm (Idle line
voltage 10 Vdc)
- Decoder for Slave -852 Hz and 1633 Hz "C" tone
- Rotary Dial
- Dial pulse rate- 8 PPS to 22 PPS
- Inter Digit time- 300 mS
- Make/break ratio-50% to 80%
- Touch Tone
- Minimum duration-40 mS
- Minimum inter digit time- 30 mS
- Sensitivity- 25 dBm to -3 dBm
- Ring Detector
- Detects metallic ringing voltage (90 Vrms)
- Line Activity- non blocking
- Cassette Recorder Output
- Separate audio output and relay contacts per line
- Audio Output
- Two line level outputs featuring Password protected audio with minimization per line
- Distortion- -<5% over 300 to 4000 Hz
- Alarms- Hold and decode
at least 8 alarm numbers
- Call counter-9999 Calls
- Mean time Between Failure- Greater
than 10,000 hours
- Power Requirement- Standard
115 Vac +_10% 50/60 Hz, 70 watts
- Size- 17.25"wide X
5.25" high X 12.75" deep
- Weight- 25 lbs Max.
|